TLT™ Shower Systems
Products
Information ARDEX TLT™ Building Panels
ARDEX TLT™ Building Panels offer builders and tile contractors a strong, lightweight, waterproof, and vapor-resistant tile base for wet areas. They are XPS foam panels manufactured with a proprietary blend of synthetic polymer mortar and an alkali-resistant fiber mesh. This gives the ARDEX TLT Building Panels a highly rigid structure and exceptional bonding strength.
Key Features
- Alkali-resistant glass fiber mesh
- Polymeric cement mortar
- XPS Foam
- Approved for steam showers via ASTM E 96-05 when Waterproofing Membrane is installed over the Building Panels
Standards
Technical Data ARDEX TLT™ Building Panels
PRODUCT | DIMENSIONS | PROPERTIES | STANDARDS | VALUES | |
---|---|---|---|---|---|
ARDEX TLT™ 102 | 3' x 5' x 1/4" | Compressive strength – perpendicular to surface | ASTM D1621 | 50.50 p.s.i. | |
ARDEX TLT™ 103 | 3' x 5' x 1/2" | Compressive strength – perpendicular to cross section | ASTM D1621 | 386.0 psi | |
ARDEX TLT™ 110 | 2' x 8' x 2" | Tensile Strength | ASTM D1623 | 75.30 psi | |
ARDEX TLT™ 114 | 4' x 5' x 1/2" | Shear Strength | ASTM D273 | 53.30 psi | |
ARDEX TLT™ 115 | 4' x 8' x 1/2" | Flexural Strength | ASTM C203 | 788 psi | |
ARDEX TLT™ 116 | 4' x 8' x 2" | Nail Pull Resistance | ASTM C473-10 | Wet 313,8 PSI/Dry 668 psi | |
ARDEX TLT™ 101 | 2' x 4' x 1/8" | Robinson Floor Test | ASTM C627 | Extra heavy duty & high impact use | |
ARDEX TLT™ 105 | 3' x 5' x 5/8" | System Crack Resistance | ANSI A 118.12, S 5.4 | No Cracks | |
ARDEX TLT™ 106 | 2' x 8' x 3/4" | Water Penetration | ASTM E331-09 | Passed | |
ARDEX TLT™ 107 | 2' x 8' x 1" | Flange-Fixture Seal | Passed | ||
ARDEX TLT™ 108 | 2' x 8' x 1 1/4" | Water Vapor Transmission – perm rating | ASTM E 96-05 | 0.494, 0.354 | |
ARDEX TLT™ 109 | 2' x 8' x 1 1/2" | Freeze & Thawing Resistance | ASTM C666 – 03 (Modified), 25 | No Visual Defects | |
ARDEX TLT™ 111 | 2' x 8' x 3 1/5" | Thermal Resistance R-Value (1/2”) | ASTM C518 | 1.8 hr. ft. 2F/Btu | |
ARDEX TLT™ 112 | 2' x 8' x 3 9/10" | Surface Burning Characteristics | ASTM E 84-16 | Classification: Class A | |
ARDEX TLT™ 113 | 3' x 8' x 1/2" | Flame speed | ASTM E84-16 | Flame Spread Index (FSI): 0 | |
ARDEX TLT™ 117 | 32" x 48" x 1/8" | Smoke Developed | ASTM E 84-16 | Developed Index (SDI): 70 | |
ARDEX TLT™ 118 | 32" x 48" x 1/4" | Flammability | NFPA 286 | Passed | |
ARDEX TLT™ 119 | 32" x 48" x 1/2" | Temperature Limits | – 50 / + 75 °C | Temperature Limits | |
ARDEX TLT™ 121 | 32" x 48" x 5/8" | Linear Co-efficient of Thermal Expansion | ASTM D696 | 0.000029 (29 x10-6) CTE / °C | |
ARDEX TLT™ 122 | 2' x 4' x 2" | Accelerated Aging | AC 71-S.3.5.3, 25 cycles | No Blistering or Delamination | |
Downloads ARDEX TLT™ Building Panels
Contact Us
Questions? Please fill out the form below to contact us with any of your questions or concerns. We look forward to hearing from you, and we’ll be in touch shortly.
"*" indicates required fields
Information ARDEX TLT™ Building Panels
ARDEX TLT™ Building Panels offer builders and tile contractors a strong, lightweight, waterproof, and vapor-resistant tile base for wet areas. They are XPS foam panels manufactured with a proprietary blend of synthetic polymer mortar and an alkali-resistant fiber mesh. This gives the ARDEX TLT Building Panels a highly rigid structure and exceptional bonding strength.
Key Features
- Alkali-resistant glass fiber mesh
- Polymeric cement mortar
- XPS Foam
- Approved for steam showers via ASTM E 96-05 when Waterproofing Membrane is installed over the Building Panels
Standards
Technical Data ARDEX TLT™ Building Panels
PRODUCT | DIMENSIONS | PROPERTIES | STANDARDS | VALUES | |
---|---|---|---|---|---|
ARDEX TLT™ 102 | 3' x 5' x 1/4" | Compressive strength – perpendicular to surface | ASTM D1621 | 50.50 p.s.i. | |
ARDEX TLT™ 103 | 3' x 5' x 1/2" | Compressive strength – perpendicular to cross section | ASTM D1621 | 386.0 psi | |
ARDEX TLT™ 110 | 2' x 8' x 2" | Tensile Strength | ASTM D1623 | 75.30 psi | |
ARDEX TLT™ 114 | 4' x 5' x 1/2" | Shear Strength | ASTM D273 | 53.30 psi | |
ARDEX TLT™ 115 | 4' x 8' x 1/2" | Flexural Strength | ASTM C203 | 788 psi | |
ARDEX TLT™ 116 | 4' x 8' x 2" | Nail Pull Resistance | ASTM C473-10 | Wet 313,8 PSI/Dry 668 psi | |
ARDEX TLT™ 101 | 2' x 4' x 1/8" | Robinson Floor Test | ASTM C627 | Extra heavy duty & high impact use | |
ARDEX TLT™ 105 | 3' x 5' x 5/8" | System Crack Resistance | ANSI A 118.12, S 5.4 | No Cracks | |
ARDEX TLT™ 106 | 2' x 8' x 3/4" | Water Penetration | ASTM E331-09 | Passed | |
ARDEX TLT™ 107 | 2' x 8' x 1" | Flange-Fixture Seal | Passed | ||
ARDEX TLT™ 108 | 2' x 8' x 1 1/4" | Water Vapor Transmission – perm rating | ASTM E 96-05 | 0.494, 0.354 | |
ARDEX TLT™ 109 | 2' x 8' x 1 1/2" | Freeze & Thawing Resistance | ASTM C666 – 03 (Modified), 25 | No Visual Defects | |
ARDEX TLT™ 111 | 2' x 8' x 3 1/5" | Thermal Resistance R-Value (1/2”) | ASTM C518 | 1.8 hr. ft. 2F/Btu | |
ARDEX TLT™ 112 | 2' x 8' x 3 9/10" | Surface Burning Characteristics | ASTM E 84-16 | Classification: Class A | |
ARDEX TLT™ 113 | 3' x 8' x 1/2" | Flame speed | ASTM E84-16 | Flame Spread Index (FSI): 0 | |
ARDEX TLT™ 117 | 32" x 48" x 1/8" | Smoke Developed | ASTM E 84-16 | Developed Index (SDI): 70 | |
ARDEX TLT™ 118 | 32" x 48" x 1/4" | Flammability | NFPA 286 | Passed | |
ARDEX TLT™ 119 | 32" x 48" x 1/2" | Temperature Limits | – 50 / + 75 °C | Temperature Limits | |
ARDEX TLT™ 121 | 32" x 48" x 5/8" | Linear Co-efficient of Thermal Expansion | ASTM D696 | 0.000029 (29 x10-6) CTE / °C | |
ARDEX TLT™ 122 | 2' x 4' x 2" | Accelerated Aging | AC 71-S.3.5.3, 25 cycles | No Blistering or Delamination | |